Plastics Engineering (SPE - Society of Plastics Engineers)· Andres Delgado·· 3h agoPulse Score58

Optical 3D Metrology Cuts False Rejects in Micro-Injection-Molded Thermoplastic Gears

Optical Metrology Improves Micro-Molded Part Accuracy

Executive Overview

Researchers from Italy used high-precision structured-light 3D scanners to measure 29 injection-molded thermoplastic gear samples from a single mold, developing a novel molding runout parameter that captured true volumetric shrinkage (-21.8 μm average displacement) versus standard runout (29.4 μm).